LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2021 >> Outback Base >> Repair and Diagnosis >> Electrical >> Gauges >> Driver Monitor (Diagnostics) >> Diagnostics With Phenomenon >> Inspection >> Heavy-Drowsiness Alarm Operates Improperly

Heavy-Drowsiness Alarm Operates Improperly

CAUTION:
  1. CHECK COMBINATION METER  .

    Perform the diagnosis for combination meter. Ref. to COMBINATION METER (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE .

    Is the check result OK?

    Yes  : Go to  2 .

    No  : Perform the diagnosis according to the inspection for the combination meter.

  2. CHECK VDC  .

    Perform the diagnosis for VDC. Ref. to BRAKE CONTROL (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE .

    Is the check result OK?

    Yes  : Go to  3 .

    No  : Perform the diagnosis according to the inspection for VDC.

  3. CHECK COCKPIT CONTROL MODULE  .

    Perform the diagnosis for cockpit control system. Ref. to COCKPIT CONTROL (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE .

    Is the check result OK?

    Yes  : Go to  4 .

    No  : Perform the diagnosis according to the inspection for cockpit control system.

  4. CHECK FOR WEARING ACCESSORY  .

    Check if the user was wearing any accessories such as glasses and sunglasses.

    Was the user wearing any accessories?

    Yes  : Ask the user to remove the accessories.

    When the trouble occurs again, Go to  5 .

    No  : Go to  5 .

  5. CHECK EYE CONDITION  .

    Check if the user was squinting when smiling or due to glaring light from outside.

    Was the user squinting?

    Yes  : Driver Monitoring System is normal.

    No  : Go to  6 .

  6. CHECK FOR DROWSINESS  .

    Check if the user felt sleepy.

    Did the user feel sleepy?

    Yes  : Driver Monitoring System is normal.

    No  : Driver Monitoring System is normal.

    NOTE: Inform the user that the recognition may not work properly with the current driver monitoring system, and have the user decide whether or not to use.