LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2021 >> Outback Base >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Power Rear Gate System >> Power Rear Gate Auto Closer >> Inspection >> Actuator

Power Rear Gate Auto Closer: Inspection: Actuator

  1. Check motor operation
    G13227246Courtesy of SUBARU OF AMERICA, INC.
    1. Check the motor operation when battery voltage is applied between the terminals of motor.
      Terminal No. Inspection conditions Specification
      4 (+) - 1 (-) Apply battery voltage. CLOSE rotation
      1 (+) - 4 (-) Apply battery voltage. OPEN rotation
    2. After the motor operation check is completed, perform initialization of the sector switch in the following procedures.
    1. Operate the motor in the OPEN direction for approximately 2 seconds.
    2. Connect the connector of power rear gate auto closer.
    3. Connect the ground terminal to the battery sensor with the rear gate fully open.
  2. Check switch
    G13227246Courtesy of SUBARU OF AMERICA, INC.
    1. Check the resistance between switch terminals.
      • Latch switch
      G13227248Courtesy of SUBARU OF AMERICA, INC.
      Terminal No. Inspection conditions Standard
      3 - 7 OPEN Less than 1 Ω
      HALF 10 kΩ or more
      FULL 10 kΩ or more
      OVER 10 kΩ or more
      • Courtesy switch
      G13227249Courtesy of SUBARU OF AMERICA, INC.
      Terminal No. Inspection conditions Standard
      7 - 8 OPEN Less than 1 Ω
      HALF Less than 1 Ω
      FULL 10 kΩ or more
      • Ratchet switch
      G13227250Courtesy of SUBARU OF AMERICA, INC.
      Terminal No. Inspection conditions Standard
      2 - 7 OPEN Less than 1 Ω
      HALF 10 kΩ or more
      FULL 10 kΩ or more
      OVER Less than 1 Ω
      • Sector switch

      Perform the check while operating the motor in the OPEN direction with the battery voltage applied between the terminals of motor.

      G13227251Courtesy of SUBARU OF AMERICA, INC.
      Terminal No. Inspection conditions Standard
      6 - 7 Switch ON (OPEN) Less than 1 Ω
      Switch OFF (NORMAL) 10 kΩ or more
    2. After the switch check is completed, perform initialization of the sector switch in the following procedures.
      1. Operate the motor in the OPEN direction for approximately 2 seconds.
      2. Connect the connector of power rear gate auto closer.
      3. Connect the ground terminal to the battery sensor with the rear gate fully open.
  3. Replace the power rear gate auto closer if it is found defective.