Adjustment Value Clear

Perform when replacing stereo camera. (Do not perform when performing stereo camera re-adjustment and inspection)

  1. Using the Subaru Select Monitor, select [Clear adjustment value] from the work support item list of [EyeSight]. Ref. to COMMON (DIAG)>WORK SUPPORT .
  2. When [Make the following adjustment/inspection. Please push OK if ready. If you finish the camera adjustment/inspection mode, you push cancel sw, and turn off IGN SW.] is displayed, select [OK] if preparation is ready.
  3. After [Clear the adjustment value. CAUTION! Perform this only under the conditions listed in the service manual.] is displayed, select [OK].
  4. When [Clearing adjustment value...] is displayed, wait until it finishes.
  5. When the adjustment value clear operation is finished correctly, [Adjustment value clear OK! Adjustment value clear is completed. Please to IG OFF more than 5 seconds. (CODE &BYTE03)] is displayed. Select [OK] to finish.
  6. Turn the ignition switch to OFF and wait for approx. 5 seconds or more.
    CAUTION: If the ignition switch OFF period is short, the adjustment value clear operation cannot be performed correctly.
  7. Next, perform the camera all adjustment mode (replacement/removal). Ref. to EYESIGHT>CAMERA ADJUSTMENT, INSPECTION>PROCEDURE>CAMERA ALL ADJUSTMENT MODE (REPLACEMENT/REMOVAL) .