Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage Barometric pressure Ambient air temperature Engine speed Vehicle speed Park/neutral position switch Time while the fuel shut-off function is in operation Compulsory drive of EGR valve delay time (low flow rate monitor only) |
10.9 V or more 75.1 kPa (563 mmHg, 22.2 inHg) or more 7°C (44.6°F) or more Value of Mapl - value of Map2 36km/h (22.4MPH) or more OFF 2000ms or more 1000ms or more |
MAP SPECIFICATION 1
| Barometric pressure (kPa (mmHg, inHg)) | 75.1 (563, 22.2 inHg) | 86.7 (650, 25.6 inHg) | 101.3 (760, 29.9 inHg) |
|---|---|---|---|
| Engine speed (rpm) | 1100rpm | 1100rpm | 1100rpm |
MAP SPECIFICATION 2
| Barometric pressure (kPa (mmHg, inHg)) | 75.1 (563, 22.2 inHg) | 86.7 (650, 25.6 inHg) | 101.3 (760, 29.9 inHg) |
|---|---|---|---|
| Engine speed (rpm) | 2000rpm | 2100rpm | 2250rpm |