Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Minimum stop position | Less than 10.036° or More than 19.964° |
| or | |
| |Throttle opening angle when the ignition switch is ON - Throttle minimum stop position| | Less than 1.07° |
Time needed for diagnosis: 8ms - 80ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.