Home >> Subaru >> 2021 >> Forester Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (Diagnostics) (3 Of 4) >> Diagnostic Procedure With Diagnostic Trouble Code (DTC) >> DTC P2004: TGV Control Stuck Open Bank 1 >> General Description >> Diagnostic Method

Diagnostic Method

If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.

JUDGMENT VALUE SPECIFICATION

Malfunction Criteria Threshold Value
Tumble generator valve opening angle 71.4 deg or more

Time needed for diagnosis:  3000ms

Malfunction indicator light illumination:  Illuminates as soon as a malfunction occurs.