DTC P0617: Starter Relay "A" Circuit High: Notes

1. - 

DTC detecting condition: 

Immediately at fault recognition

Trouble symptom: 

Failure of engine to start

Wiring diagram: 

Engine Electrical System Ref. to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM .

G13589230Courtesy of SUBARU OF AMERICA, INC.
G13891323Courtesy of SUBARU OF AMERICA, INC.
G13891324Courtesy of SUBARU OF AMERICA, INC.
G13589234Courtesy of SUBARU OF AMERICA, INC.
CAUTION: Use the check board when measuring the ECM terminal voltage and resistance. Ref. to ENGINE (DIAGNOSTICS) (H4DO)>GENERAL DESCRIPTION>PREPARATION TOOL>HOW TO USE CHECK BOARD .
NOTE: After the faulty parts are repaired or replaced, perform the final check in Basic Diagnostic Procedure. Ref. to ENGINE (DIAGNOSTICS) (H4DO)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE .
  1. CHECK DTC  .
    1. Turn the ignition switch to ON.
    2. Using the Subaru Select Monitor or a general scan tool, read the DTC of [Engine].

      Ref. to COMMON (DIAG)>DIAGNOSTIC TROUBLE CODE (DTC) .

    Is DTC other than P0617 displayed? (Current malfunction)

    Yes  : Check the appropriate DTC using the "Diagnostic Trouble Code (DTC)". Ref. to ENGINE (DIAGNOSTICS) (H4DO)>DIAGNOSTIC TROUBLE CODE (DTC) .

    No  : Go to  2 .

  2. CHECK HARNESS BETWEEN ECM AND M/B (STARTER RELAY) (SHORT TO POWER SUPPLY)  .
    1. Turn the ignition switch to OFF.
    2. Disconnect the connector from ECM.
    3. Turn the ignition switch to ON.
    4. Measure the voltage between ECM connector and engine ground.

      Connector and terminal 

      (B134) No. 27 (+) - Engine ground (-):

    Is the voltage 10 V or more?

    Yes  : Repair the following item.

    • Short circuit to power supply in harness between ECM connector and M/B (starter relay)
    • Short circuit to power supply in harness between ECM connector and starter motor

    No  : Repair the poor contact of ECM connector.