Diagnostic Method
Compare the diagnostic value with the threshold value, and if a condition meeting the malfunction criteria continues for 10s x 3time(s) or more, judge that there is a fault in the fuel system.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Offset amount of main feedback compensation | Value of Map or more |
MAP SPECIFICATION
| Amount of air (g/s(oz/s)) | 0 (0) | 3.2 (0.11) |
|---|---|---|
| Threshold Value | 1.35 | 1.35 |
Time needed for diagnosis : 10s x 3time(s)
Malfunction indicator light illumination : Illuminates when malfunction occurs in 2 continuous driving cycles.