Diagnostic Method 2
Detect the malfunction by calculating the average amplitude of A.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Average value for λ amplitude | More than 0.075 |
Time needed for diagnosis : 90 s
Malfunction indicator light illumination : Illuminates when malfunction occurs in 2 continuous driving cycles.