DTC B1576: EGI Control Module EEPROM
Diagnosis start condition:
- Battery voltage is 10 V or more.
- The remote engine starter was not used to start the engine.
DTC detecting condition:
- ECM malfunctioning
- Failed to access ROM in ECM during key registration.
Trouble symptom:
- Engine will not start.
- The security indicator illuminates.
- PERFORM ECM REGISTRATION
.
Perform ECM registration. Refer to the "REGISTRATION MANUAL FOR IMMOBILIZER" provided as a separate volume.
Is registration complete?
Yes : Finish the diagnosis.
No : Go to 2 .
- PERFORM ECM REGISTRATION
.
Perform ECM registration. Refer to the "REGISTRATION MANUAL FOR IMMOBILIZER" provided as a separate volume.
Is registration complete?
Yes : Finish the diagnosis.
No : Go to 3 .
- PERFORM ECM REGISTRATION
.
Perform ECM registration. Refer to the "REGISTRATION MANUAL FOR IMMOBILIZER" provided as a separate volume.
Is registration complete?
Yes : Finish the diagnosis.
No : Refer to "Correspondence table when registration is not possible" in the "REGISTRATION MANUAL FOR IMMOBILIZER" provided as a separate volume. If the registration still does not work properly, replace the ECM. Ref. to FUEL INJECTION (FUEL SYSTEMS) (H4DO)>ENGINE CONTROL MODULE (ECM) .