G13200933Courtesy of SUBARU OF AMERICA, INC.
  1. Check the resistance between relay terminals.
    Inspection conditions Terminal No. Standard
    Always A1 - A2 Less than 1 Ω
    A4 - A1 1 MΩ or more
    A3 - A4 1 MΩ or more
    Apply battery voltage between terminals B3 (+) and B2 (-). (Lo output condition) A1 - A2 1 MΩ or more
    A4 - A1 Less than 1 Ω
    A3 - A4 1 MΩ or more
    Apply battery voltage between terminals B1 (+) and B2 (-). (Hi output condition) A1 - A2 1 MΩ or more
    A4 - A1 1 MΩ or more
    A3 - A4 Less than 1 Ω
  2. When measurement value is different from the specification, replace the wiper relay unit.