Diagnostic Method
Judge as NG when the following conditions are established.
Diagnosis 1
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Amount of crankshaft position sensor signals during 0.5 revs of crankshaft | Less than 13 Or, 19 or more |
Diagnosis 2
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| |(Present value of diagnosis 1) -(Previous value of diagnosis 1)| | Not equal to 1 |
Time needed for diagnosis: 10 crankshaft rotations
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.