Execution Condition
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 1
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 10.9 V or more |
| Barometric pressure | 75.06 kPa (563.1 mmHg, 22.2 inHg) or more |
| Operation time of main feedback | 5000 ms or more |
| Engine speed | 1000 rpm or more |
| Amount of intake air | 10 g/s (0.35 oz/s) or more |
SECONDARY PARAMETERS AND EXECUTION CONDITION - DIAGNOSIS 2
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 10.9 V or more |
| Barometric pressure | 75.06 kPa (563.1 mmHg, 22.2 inHg) or more |
| Main feedback | In operation |
| Engine speed | 1000 rpm or more |
| Amount of intake air | 20 g/s (0.7 oz/s) or more and Less than 100 g/s (3.5 oz/s) |
| Change amount of intake air | 0.5 g/s (0.02 oz/s) or more |