DTC U171F: Lost Lin Communication With Generator: Notes

  1. DTC detecting condition: 

    Immediately at fault recognition

    Wiring diagram: 

    Engine Electrical system. Refer to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM .

    G13626992Courtesy of SUBARU OF AMERICA, INC.
    CAUTION: Use the check board when measuring the ECM terminal voltage and resistance. Refer to ENGINE (DIAGNOSTICS) (H4DO)>GENERAL DESCRIPTION>PREPARATION TOOL>HOW TO USE CHECK BOARD .
    NOTE: After the faulty parts are repaired or replaced, perform the final check in Basic Diagnostic Procedure. Refer to ENGINE (DIAGNOSTICS) (H4DO)>Basic Diagnostic Procedure>PROCEDURE .
  1. CHECK DTC  .
    1. Turn the ignition switch to ON.
    2. Using the Subaru Select Monitor or a general scan tool, read the DTC of [Engine]. Refer to COMMON (DIAG)>DIAGNOSTIC TROUBLE CODE (DTC) .

      Is DTC U171F displayed? (Current malfunction)

      Yes  : Go to  2.

      No  : Even if DTC is detected, the circuit has returned to a normal condition at this time.

      Reproduce the failure, and then perform the diagnosis again.

  2. CHECK ECM CONNECTOR  .

    Check the connecting condition of ECM connector.

    Is the ECM connector correctly connected?

    Yes  : Go to  3.

    No  : Connect the ECM connector correctly.

  3. CHECK VOLTAGE OF GENERATOR B TERMINAL  .
    1. Turn the ignition switch to OFF.
    2. Disconnect the ground terminal from battery sensor. Refer to REPAIR CONTENTS>NOTE>BATTERY .
    3. Measure the voltage of the generator B terminal.

      Connector & terminal 

      Generator B terminal - Engine ground:

      Is the voltage battery voltage?

      Yes  : Go to  4.

      No  : Check the generator B terminal harness and fuse.

  4. CHECK HARNESS BETWEEN ECM CONNECTOR AND GENERATOR CONNECTOR (OPEN)  .
    1. Disconnect the connector from ECM.
    2. Disconnect the LIN communication connector from the generator.
    3. Measure the resistance of harness between ECM and generator LIN communication connector.

      Connector & terminal 

      (B62) No. 17 - (Bt52) No. 1:

      Is the resistance less than 1 Ω?

      Yes  : Check the connector for poor contact and check the harness again. If no fault is found, replace the generator. Refer to STARTING/CHARGING SYSTEMS (H4DO)>GENERATOR .

      No  : Repair the following item.

      • Open circuit of harness between ECM connector and generator