Solenoid Unit
- Remove the select lever. Refer to CONTROL SYSTEMS>SELECT LEVER>REMOVAL .
- Remove the spacer and gasket. Refer to CONTROL SYSTEMS>SELECT LEVER>DISASSEMBLY>SELECT LEVER .
- Remove the connector.
- Raise the claw with a flat tip screwdriver, etc. and remove the solenoid unit.
- Pull out the terminal of the solenoid unit using KTC connector terminal tool (part number: ECC-1T).NOTE: A flat tip precision screwdriver with a tip width of 1.3 mm (0.05 in) or less can also be used.
Terminal No. Wiring color 3 Blue 4 Black