Check Ambient Temperature Meter System Communication Circuit

  1. CHECK AMBIENT SENSOR POWER SUPPLY. 
    1. Disconnect the ambient sensor connector.
    2. Turn the ignition switch to ON.
    3. Measure the voltage between the ambient sensor connector and chassis ground.

    Connector & terminal 

    (B480) No. 2 (+) - Chassis ground (-):

    Is the voltage 4 V or more?

    Yes

    Go to  2.

    No

    Check the harness for open or short between the fuse and ambient sensor.

  2. CHECK HARNESS BETWEEN AMBIENT SENSOR AND COMBINATION METER ASSEMBLY. 
    1. Disconnect the connector of combination meter assembly.
    2. Check harness between ambient sensor and combination meter assembly.

    Connector & terminal 

    (B480) No. 1 - (i10) No. 24:

    (B480) No. 2 - (i10) No. 23:

    Is harness normal?

    Yes

    Go to  3.

    No

    Repair or replace the harness.

  3. CHECK AMBIENT SENSOR. 

    Check the ambient sensor.

    Is the ambient sensor operating properly? Refer to AIR CONDITIONER>AMBIENT SENSOR>INSPECTION .

    Yes

    Go to  4.

    No

    Replace the ambient sensor.

  4. CHECK AMBIENT TEMPERATURE DISPLAY. 
    1. Connect the combination meter assembly connector.
    2. Install the 3 kΩ resistance between connector terminals of the ambient sensor.
    3. Turn the ignition switch to ON.

    Connector & terminal 

    (B480) No. 1 - No. 2:

    Does the ambient temperature display 25°C (77°F)?

    Yes

    Repair the poor contact between the ambient sensor and harness connector.

    No

    Go to  5.

  5. CHECK CURRENT DATA. 

    Display the [Ambient Air Temperature] data using Subaru Select Monitor. Refer to AIR CONDITIONER (DIAGNOSTICS)>DATA MONITOR .

    Is the ambient temperature of 25°C (77°F) output?

    Yes

    Go to  6.

    No

    Replace the combination meter assembly. Refer to INSTRUMENTATION/DRIVER INFO>COMBINATION METER .

  6. CHECK MFD. 
    1. Remove the MFD.
    2. Attach the ambient temperature display to another vehicle on which the ambient temperature display operates normally to check its operation.

    Does the ambient temperature display 25°C (77°F)?

    Yes

    Replace MFD.

    No

    Replace the combination meter assembly. Refer to INSTRUMENTATION/DRIVER INFO>COMBINATION METER .