Model Without Keyless Access With Push Button Start
- Disconnect the ground cable from battery and wait for at least 60 seconds before starting work.
Refer to NOTE>NOTE>BATTERY .
NOTE: For model with battery sensor, disconnect the ground terminal from battery sensor. - Remove the cover assembly - column.
- Remove the immobilizer antenna assembly.
- Disconnect the connector.
- Release two claws using a flat tip screwdriver or similar tool wrapped with a protection tape, and remove the immobilizer antenna assembly.CAUTION: Do not apply excessive force to disengage the lock of immobilizer antenna assembly. Otherwise they may be broken because those parts are the products made of a plastic.