Execution Condition
SECONDARY PARAMETERS AND EXECUTION CONDITION - JUDGMENT 1 (INSTRUCTION CHECK - A)
| Secondary parameters | Execution condition |
|---|---|
| Initial routine Main CPU | Execution in progress |
SECONDARY PARAMETERS AND EXECUTION CONDITION - JUDGMENT 1 (INSTRUCTION CHECK - B)
| Secondary parameters | Execution condition |
|---|---|
| Ignition switch | ON |
| Battery voltage | ≥ 6.2V |
| Electronic throttle control relay | ON |
SECONDARY PARAMETERS AND EXECUTION CONDITION - JUDGMENT 2 (SOFT FLOW CHECK)
| Secondary parameters | Execution condition |
|---|---|
| (2) Ignition switch | ON |
SECONDARY PARAMETERS AND EXECUTION CONDITION - JUDGMENT 3 (SOFT MONITOR CHECK)
| Secondary parameters | Execution condition |
|---|---|
| Ignition switch | ON |
| Battery voltage | ≥ 6.2V |
| Electronic throttle control relay | ON |
SECONDARY PARAMETERS AND EXECUTION CONDITION - JUDGMENT 4 (IF OUTPUT IC OPERATION IS ABNORMAL)
| Secondary parameters | Execution condition |
|---|---|
| Ignition switch | ON |
SECONDARY PARAMETERS AND EXECUTION CONDITION - JUDGMENT 5 (CAN REGISTER CHECK)
| Secondary parameters | Execution condition |
|---|---|
| (5) Initial routine | Execution in progress |