Diagnostic Method
Compare the diagnostic value with the threshold value, and if a condition meeting the malfunction criteria listed below continues for 10s x 3time(s) or more, judge that there is a fault in the fuel system.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Offset amount of main feedback compensation | ≥ 1.35 |
time needed for diagnosis: 10s x 3time(s)
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.