Diagnostic Method
Diagnosis 1
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Engine speed | < 500 rpm |
Time needed for diagnosis: 2 - 26 seconds
Diagnosis 2
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Engine speed | < 300 rpm |
Time needed for diagnosis: Less than 1 second
Malfunction indicator light illumination: Does not illuminate.