Diagnostic Method
Measure the pressure values when the enable conditions are established, and perform diagnosis by calculating those results.
- Label the intake manifold pressure value as PMOF1, which is observed when enable conditions are established, and set the EGR target step to 55 steps (nearly full open).
- Label the intake manifold pressure value as PMON, which is observed after one second has passed since EGR target step was set to 55 steps (when the enable conditions were established), and set the EGR target step to 0.
- Label the intake manifold pressure as PMOF2, which is observed after one second has passed since EGR target step was set to 0 (after two seconds have passed since the enable conditions were established).
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| PMON - (PMOF1 + PMOF2)/2 | < 2.48 kPa (18.6 mmHg, 0.7 inHg) |
Time needed for diagnosis: 2 seconds
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.