Symptom Chart
| Symptoms | Repair order | Reference |
|---|---|---|
| The door lock control system does not operate. | 1. Remove and visually inspect the following fuses.
|
If the fuse is blown out, replace the fuse with a new part. When there is no defective with the fuse, check the power supply and ground circuit. Refer to SECURITY AND LOCKS>DOOR LOCK CONTROL SYSTEM>INSPECTION>CHECK POWER SUPPLY AND GROUND CIRCUIT . |
| 2. Check the power supply and ground circuit for body integrated unit. | Refer to SECURITY AND LOCKS>DOOR LOCK CONTROL SYSTEM>INSPECTION>CHECK POWER SUPPLY AND GROUND CIRCUIT . | |
| 3. Check the door lock switch and the circuit. | Refer to SECURITY AND LOCKS>DOOR LOCK CONTROL SYSTEM>INSPECTION>CHECK DOOR LOCK SWITCH . | |
| 4. Check the trunk opener switch and the circuit. | Refer to SECURITY AND LOCKS>DOOR LOCK CONTROL SYSTEM>INSPECTION>CHECK TRUNK OPENER SWITCH CIRCUIT . | |
| 5. Check the door lock actuator and the circuit. | Refer to SECURITY AND LOCKS>DOOR LOCK CONTROL SYSTEM>INSPECTION>CHECK DOOR LOCK ACTUATOR AND CIRCUIT . | |
| A specific door lock actuator does not operate. | Check the door lock actuator and circuit. | Refer to SECURITY AND LOCKS>DOOR LOCK CONTROL SYSTEM>INSPECTION>CHECK DOOR LOCK ACTUATOR AND CIRCUIT . |