DTC P2009: TGV Control Circuit Low Bank 1: Notes
DTC detecting condition:
Immediately at fault recognition
CAUTION:
- After servicing or replacing faulty parts, perform Clear Memory Mode Refer to ENGINE (DIAGNOSTICS) (EXCEPT FOR STI)>CLEAR MEMORY MODE>OPERATION , and inspection mode Refer to ENGINE (DIAGNOSTICS) (EXCEPT FOR STI)>INSPECTION MODE>PROCEDURE ..
- Use the check board when measuring the ECM terminal voltage and resistance.
Wiring diagram:
Engine Electrical System Refer to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM>WIRING DIAGRAM .
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR.
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Measure the voltage between ECM connector and engine ground.
Connector & terminal
(E159) No. 14 (+) - Engine ground (-):
(E159) No. 30 (+) - Engine ground (-):
Is the voltage 5 V or more?
Yes: Repair the short circuit to power in harness between ECM connector and tumble generator valve actuator RH connector.
No: Replace the tumble generator valve actuator RH. Refer to FUEL INJECTION (FUEL SYSTEMS) (EXCEPT FOR STI)>TUMBLE GENERATOR VALVE ACTUATOR .
NOTE: The tumble generator valve actuator cannot be disassembled.