DTC P2402: EVAP System Leak Detection Pump Control Circuit High: Notes
DTC detecting condition:
Immediately at fault recognition
CAUTION:
- After servicing or replacing faulty parts, perform Clear Memory Mode Refer to ENGINE (DIAGNOSTICS) (EXCEPT FOR STI)>CLEAR MEMORY MODE>OPERATION , and inspection mode Refer to ENGINE (DIAGNOSTICS) (EXCEPT FOR STI)>INSPECTION MODE>PROCEDURE ..
- Use the check board when measuring the ECM terminal voltage and resistance.
Wiring diagram:
Engine Electrical System Refer to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM>WIRING DIAGRAM .
- CHECK HARNESS BETWEEN ECM AND LEAK CHECK VALVE ASSEMBLY CONNECTOR.
- Turn the ignition switch to OFF.
- Disconnect the connector from the leak check valve assembly.
- Turn the ignition switch to ON.
- Measure the voltage between leak check valve assembly and chassis ground.
Connector & terminal
(R400) No. 4 (+) - Chassis ground (-):
Is the voltage 10 V or more?
Yes: Repair the short circuit to power in harness between ECM connector and leak check valve assembly connector.
No: Go to 2.
- CHECK LEAK CHECK VALVE ASSEMBLY.
- Turn the ignition switch to OFF.
- Check the vacuum pump of the leak check valve assembly. Refer to EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) (EXCEPT FOR STI)>LEAK CHECK VALVE ASSEMBLY>INSPECTION>CHECK VACUUM PUMP .
Is the check result OK?
Yes: Repair the poor contact in the leak check valve assembly connector.
No: Replace the leak check valve assembly. Refer to EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) (EXCEPT FOR STI)>LEAK CHECK VALVE ASSEMBLY .