Execution Condition
| Secondary parameters | Execution condition | ||
|---|---|---|---|
| <Phase1> Battery voltage |
≥ 10.9 V | ||
| Barometric pressure | ≥ 75.06 kPa (563 mmHg, 22.2 inHg) | ||
| Integrated purge air amount since engine starting | ≥ 72 g (2.54 oz)(1) | ||
| Purge control duty ratio = 0% duration time | ≥ 1 s | ||
| Ambient air temperature | > 4.4°C (39.9°F) and < 35°C (95°F) |
||
| Fuel level | ≥ 9 L (2.38 US gal, 1.98 Imp gal) | ||
| Cumulative time for establishment of the following conditions | ≥ 6 s | ||
|
> Map | ||
|
Open | ||
| <Phase2> Battery voltage |
≥ 10.9 V | ||
| Barometric pressure | ≥ 75.06 kPa (563.1 mmHg, 22.2 inHg) | ||
| Fuel level | ≥ 9 L (2.38 US gal, 1.98 Imp gal) | ||
| Establishing time of Phase 2 | ≥ 20 s | ||
|
|||
MAP SPECIFICATION
| Fuel level (L (US gal, Imp gal)) | 9 (2.38, 1.98) | 10 (2.64, 2.2) | 20 (5.28, 4.4) | 30 (7.93, 6.6) | 40 (10.57, 8.8) | 50 (13.21, 11) | 60 (15.85, 13.2) |
| Intake air amount per 1 second (g/s) | 80 | 80 | 60 | 60 | 60 | 60 | 60 |