Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Main feedback | In operation |
| Rear oxygen sensor voltage when fuel cut has completed | < 0.15 V |
| (Time of fuel shut-off operation Fuel shut-off function after the experience above) | > 3 s Not in operation |
| Estimated temperature of the rear oxygen sensor element | > 450°C (842°F) |
| Compensation to rich | Rich Amount of intake air ≥ 15 g/s (0.5 oz/s) |