LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2019 >> WRX Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (Diagnostics) (Except For STI) (1 Of 4) >> Diagnostic Procedure With Diagnostic Trouble Code (DTC) >> DTC P013A: O2 Sensor Slow Response - Rich To Lean Bank 1 Sensor 2 >> Notes

DTC P013A: O2 Sensor Slow Response - Rich To Lean Bank 1 Sensor 2: Notes

DTC detecting condition: 

Detected when two consecutive driving cycles with fault occur.

CAUTION:

Wiring diagram: 

Engine Electrical System Refer to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM>WIRING DIAGRAM .

G11577050Courtesy of SUBARU OF AMERICA, INC.
  1. CHECK HARNESS BETWEEN ECM AND REAR OXYGEN SENSOR CONNECTOR. 
    1. Turn the ignition switch to OFF.
    2. Disconnect the connector from ECM.
    3. Disconnect the connector from rear oxygen sensor.
    4. Measure the resistance of harness between ECM connector and rear oxygen sensor connector.

      Connector & terminal 

      (E158) No. 16 - (E25) No. 4:

    Is the resistance less than 1 Ω?

    Yes:  Go to  2.

    No:  Repair the open circuit of harness between ECM connector and rear oxygen sensor connector.

  2. CHECK HARNESS BETWEEN ECM AND REAR OXYGEN SENSOR CONNECTOR. 

    Measure the resistance between rear oxygen sensor connector and engine ground.

    Connector & terminal 

    (E25) No. 4 - Engine ground:

    Is the resistance 1 MΩ or more?

    Yes:  Go to  3.

    No:  Repair the short circuit to ground in harness between ECM connector and rear oxygen sensor connector.

  3. CHECK REAR OXYGEN SENSOR. 

    Measure the resistance between rear oxygen sensor terminals.

    Terminals 

    No. 3 - No. 4

    Is the resistance less than 1 Ω?

    Yes:  Replace the rear oxygen sensor. Refer to FUEL INJECTION (FUEL SYSTEMS) (EXCEPT FOR STI)>REAR OXYGEN SENSOR .

    No:  Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.

    NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.