LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2019 >> WRX Base >> Repair and Diagnosis (Single Page) >> Body & Frame >> Door Locks >> Security And Locks - Keyless Access (W/Push Button Start) (Diagnostics) >> Diagnostic Procedure With Diagnostic Trouble Code (DTC) >> DTC B2274: ACC Relay Control Circuit

DTC B2274: ACC Relay Control Circuit

DTC detecting condition: 

When any of the following is established.

Trouble symptom: 

Each function does not operate at the ACC position.

CAUTION:

Wiring diagram: 

  1. CHECK LAN SYSTEM. 

    Perform the diagnosis for LAN system. Refer to LAN SYSTEM (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE .

    Is the check result OK?

    Yes:  Go to  2.

    No:  Perform the inspection according to the diagnosis for LAN system.

  2. CHECK FUSE. 

    Check the fuse. Refer to SECURITY AND LOCKS>RELAY AND FUSE .

    Is the check result OK?

    Yes:  Go to  3.

    No:  Replace the fuse. When the replaced fuse is blown immediately, check the power supply circuit for short-circuited.

  3. CHECK HARNESS. 
    1. Disconnect the keyless access control module connector.
    2. Using a tester, measure the voltage between the keyless access control module connector and chassis ground.

      Connector & terminal 

      (B573) No. 1 (+) - Chassis ground (-):

      (B573) No. 4 (+) - Chassis ground (-):

      Is the voltage 9.5 - 16 V?

      Yes:  Go to  4.

      No:  Check the power supply circuit.

  4. CHECK HARNESS (OPEN CIRCUIT). 

    Using a tester, measure the resistance between the keyless access control module connector and chassis ground.

    Connector & terminal 

    (B574) No. 17 - Chassis ground:

    (B573) No. 20 - Chassis ground:

    Is the resistance less than 1 Ω?

    Yes:  Go to  5.

    No:  Repair or replace the open circuit of harness.

  5. CHECK HARNESS. 
    1. Disconnect the keyless access control module connector.
    2. Using a tester, measure the resistance between the keyless access control module connector and chassis ground.

      Connector & terminal 

      (B573) No. 16 - Chassis ground:

      Is resistance 152.61 - 216.5 Ω? (20°C)

      Yes:  Go to  7.

      No:  Go to  6.

  6. CHECK RELAY. 

    Perform inspection of ACC relay unit. Refer to SECURITY AND LOCKS>RELAY AND FUSE .

    Is the check result OK?

    Yes:  Go to  7.

    No:  Replace the relay.

  7. CHECK HARNESS (OPEN CIRCUIT). 

    Using a tester, measure the resistance between the keyless access control module connector and the accessory relay (push button start), and between the accessory relay (push button start) and chassis ground.

    Connector & terminal 

    (B573) No. 16 - (B426) No. 1:

    (B426) No. 2 - Chassis ground:

    Is the resistance less than 1 Ω?

    Yes:  Go to  8.

    No:  Repair or replace the open circuit of harness.

  8. CHECK KEYLESS ACCESS control module. 
    1. Connect the keyless access control module connector.
    2. Using a tester, measure the voltage between the keyless access control module connector and chassis ground.

      Connector & terminal 

      (B573) No. 16 (+) - Chassis ground (-):

      Is the voltage 1 V or less → 9.5 - 16 V when OFF → ACC ON?

      Yes:  Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.

      NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.

      No:  Replace the keyless access control module. Refer to SECURITY AND LOCKS>KEYLESS ACCESS control module .