LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2019 >> Outback 2.5i >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Engine Starting System & Charging System (3.6L)) >> General Description >> Specification

Section 1 (Engine Starting System & Charging System (3.6L)): General Description: Specification

WARNING: This page is about a different variant/trim than selected.
Item Specifications
Starter Type Reduction type
Model M000T20176ZC
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 1.4 kW
Direction of rotation Counterclockwise (when observed from pinion)
Number of pinion teeth 9
No-load characteristics Voltage 11 V
Current 90 A or less
Generator Type Rotating-field three-phase type, voltage regulator built-in type, each with load response control system
Model A2TX6491
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 130 A
Polarity on ground side Negative
Direction of rotation Clockwise (when observed from pulley side)
Stator connection 3-phase Δ type
Output current 1, 500 r/min - 50 A or more
2, 500 r/min - 111 A or more
5, 000 r/min - 133 A or more
Regulated voltage 14.1 - 14.8 V [20°C (68°F)]
Rotor slip ring outer diameter Standard 22.7 mm (0.894 in)
Limit 22.1 mm (0.870 in)
Brush length Standard 22.5 mm (0.886 in)
Limit 5.0 mm (0.197 in)
Battery Type 75D23R
Nominal capacity 5 HR: 52 Ah [25°C (77°F)]
Nominal voltage 12 V
CCA 490 A
BCI group number(1) 35
(1) This is a reference information for battery size, and is not guaranteed by SUBARU CORPORATION.