Immobilizer Cm

Detecting condition: 

Trouble symptom: 

Not communicable with Subaru Select Monitor.

Wiring diagram: 

Immobilizer system Ref. to WIRING SYSTEM>IMMOBILIZER SYSTEM>WIRING DIAGRAM .

G12409825Courtesy of SUBARU OF AMERICA, INC.
  1. CHECK FUSE  .

    Check the fuse.

    Is the check result OK?

    Yes: Go to  2 .

    No: Replace the fuse. If the replaced fuse blows out easily, repair the ground short circuit in the harness between the battery and immobilizer CM.

  2. CHECK LAN SYSTEM  .

    Inspect LAN system. Ref. to LAN SYSTEM (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE .

    Is the check result OK?

    Yes: Go to  3 .

    No: Perform the inspection according to the diagnosis for LAN system.

  3. CHECK HARNESS  .
    1. Turn the ignition switch to OFF.
    2. Disconnect the immobilizer CM connector.
    3. Turn the ignition switch to ON.
    4. Using a tester, measure the voltage between the immobilizer CM connector and chassis ground.

    Connector & terminal 

    (i34) No. 2 (+) - Chassis ground (-):

    (i34) No. 1 (+) - Chassis ground (-):

    Is the voltage 10 - 13 V?

    Yes: Go to  4 .

    No: Repair the open circuit of harness between the immobilizer CM connector and fuse.

  4. CHECK HARNESS  .

    Using a tester, measure the resistance between the immobilizer CM connector and chassis ground.

    Connector & terminal 

    (i34) No. 16 - Chassis ground:

    Is the resistance less than 1 Ω?

    Yes: Go to  5 .

    No: Repair the open circuit of harness between the immobilizer CM connector and chassis ground.

  5. CHECK IMMOBILIZER CM  .
    1. Turn the ignition switch to OFF.
    2. Connect the immobilizer CM connector.
    3. Perform communication with the immobilizer CM.

    Is communication possible?

    Yes: The circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.

    NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.

    No: Replace the immobilizer CM. Ref. to SECURITY AND LOCKS>IMMOBILIZER CONTROL MODULE .