Diagnostic Method
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnosis 1 Internal malfunction flag of generator (mechanical malfunction warning) and |
ON |
| Generator revolution speed | 1300rpm is exceeded |
| Diagnosis 2 Internal malfunction flag of generator (electrical malfunction warning) |
ON |
time needed for diagnosis :0ms or more (diagnosis 1)
time needed for diagnosis: 1024ms or more (diagnosis 2 (delay of 2000 ms occurs inside the generator))
Malfunction indicator light illumination: Does not illuminate even when malfunction occurs. (Charge warning light illuminates.)