Diagnostic Method
Judge as NG when Low side or High side becomes NG.
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Low | |
| Output voltage | < 2.31V |
| High Output voltage |
≥2.31V |
Time needed for diagnosis:
Low side: 5000ms
High side: 5000ms
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.