DTC P2017: TGV Position Sensor/Switch Circuit High Bank 1: Notes
- -
DTC detecting condition:
Immediately at fault recognition
Trouble symptom:
- Improper idling
- Engine stall
- Poor driving performance
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM .
- CHECK DATA MONITOR
.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].NOTE: For detailed operation procedures, refer to "Common (Diagnostics)". Ref. to COMMON(DIAG)>DATA MONITOR .
Is the value of [TGV Position Sensor R] 5 V or more?
Yes
Go to 2 .
No
Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR (SHORT TO POWER SUPPLY)
.
- Turn the ignition switch to OFF.
- Disconnect the connector from tumble generator valve actuator RH.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].NOTE: For detailed operation procedures, refer to "Common (Diagnostics)". Ref. to COMMON(DIAG)>DATA MONITOR .
Is the value of [TGV Position Sensor R] 5 V or more?
Yes
Repair the short circuit to power in harness between ECM connector and tumble generator valve actuator RH connector.
No
Go to 3 .
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR (OPEN)
.
- Turn the ignition switch to OFF.
- Measure the resistance of harness between tumble generator valve actuator RH connector and engine ground.
Connector & terminal
(E55) No. 2 - Engine ground:
Is the resistance less than 5 Ω?
Yes
Go to 4 .
No
Repair the following item.
- Open circuit in harness between ECM connector and tumble generator valve actuator RH connector
- Poor contact of ECM connector
- CHECK FOR POOR CONTACT
.
Check for poor contact of tumble generator valve actuator RH connector.
Is there poor contact of the tumble generator valve actuator RH connector?
Yes
Repair the poor contact of tumble generator valve actuator RH connector.
No
Replace the tumble generator valve actuator RH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (H4DO)>TUMBLE GENERATOR VALVE ACTUATOR .
NOTE: The tumble generator valve actuator cannot be disassembled.