LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2019 >> Forester Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (Diagnostics) (3 Of 4) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P2008: TGV Control Circuit/Open Bank 1 >> Notes

DTC P2008: TGV Control Circuit/Open Bank 1: Notes

  1. DTC detecting condition: 

    Immediately at fault recognition

    Wiring diagram: 

    Engine Electrical System Ref. to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM .

G13228028Courtesy of SUBARU OF AMERICA, INC.
CAUTION: Use the check board when measuring the ECM terminal voltage and resistance. Ref. to ENGINE (DIAGNOSTICS) (H4DO)>GENERAL DESCRIPTION>PREPARATION TOOL>HOW TO USE CHECK BOARD .
NOTE: After the faulty parts are repaired or replaced, perform the final check in Basic Diagnostic Procedure. Ref. to ENGINE (DIAGNOSTICS) (H4DO)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE .
  1. CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR (OPEN)  .
    1. Turn the ignition switch to OFF.
    2. Disconnect the connector from ECM.
    3. Disconnect the connector from tumble generator valve actuator RH.
    4. Measure the resistance of harness between ECM connector and tumble generator valve actuator RH connector.

      Connector & terminal 

      (E158) No. 102 - (E55) No. 5:

      (E158) No. 111 - (E55) No. 4:

      Is the resistance less than 1 Ω?

      Yes

      Go to  2 .

      No

      Repair the open circuit in harness between ECM connector and tumble generator valve actuator RH connector.

  2. CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR (SHORT TO GROUND)  .

    Measure the resistance between the ECM connector and engine ground.

    Connector & terminal 

    (E158) No. 102 - Engine ground:

    (E158) No. 111 - Engine ground:

    Is the resistance 1 MΩ or more?

    Yes

    Go to  3 .

    No

    Repair the short circuit to ground in harness between ECM connector and tumble generator valve actuator RH connector.

  3. CHECK FOR POOR CONTACT  .

    Check for poor contact in the tumble generator valve actuator RH connector.

    Is there poor contact of the tumble generator valve actuator RH connector?

    Yes

    Repair the poor contact of tumble generator valve actuator RH connector.

    No

    Replace the tumble generator valve actuator RH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (H4DO)>TUMBLE GENERATOR VALVE ACTUATOR .

    NOTE: The tumble generator valve actuator cannot be disassembled.