DTC B227B: Push Engine Start Switch Input Performance: Wiring diagram
Keyless access with push button start system Ref. to WIRING SYSTEM>KEYLESS ACCESS WITH PUSH BUTTON START SYSTEM>WIRING DIAGRAM .
- For replacement procedure of keyless access Control Module, refer to the "REGISTRATION MANUAL FOR IMMOBILIZER" provided as a separate volume.
- Before performing diagnosis, refer to "CAUTION" in "General Description". Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>GENERAL DESCRIPTION>CAUTION .
- CHECK DTC
.
- Using the Subaru Select Monitor, perform the clear memory of [Keyless Access with Push Button Start]. Ref. to COMMON(DIAG)>CLEAR MEMORY .
- Press the push button ignition switch to perform OFF → ACC ON → IGN ON respectively for one minute.
- Disconnect and reconnect the keyless access Control Module connector.
- Read the DTC of [Keyless Access with Push Button Start] using the Subaru Select Monitor.
Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .
Is DTC B227B displayed? (Current malfunction)
Yes : Go to 2 .
No : Even if DTC is displayed, the circuit has returned to a normal condition at this time.
Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
- CHECK HARNESS (OPEN CIRCUIT)
.
- Disconnect the push button ignition switch connector.
- Disconnect the keyless access Control Module connector.
- Using a tester, measure the resistance between the push button ignition switch connector and the keyless access Control Module connector and chassis ground.
Connector & terminal
(i150) No. 2 - (i75) No. 9:
(i150) No. 7 - (i75) No. 8:
(i150) No. 5 - Chassis ground
Is the resistance less than 1 Ω?
Yes : Go to 3 .
No : Repair or replace the open circuit of harness.
- CHECK PUSH BUTTON IGNITION SWITCH UNIT
.
Perform individual inspection of the push button ignition switch. Ref. to SECURITY AND LOCKS>PUSH BUTTON IGNITION SWITCH .
Is the check result OK?
Yes : Go to 4 .
No : Replace the push button ignition switch. Ref. to SECURITY AND LOCKS>PUSH BUTTON IGNITION SWITCH .
- CHECK DATA MONITOR
.
Using the Subaru Select Monitor, check the following items in the [Data Monitor] of [Keyless Access with Push Button Start]. Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>DATA MONITOR .
- Push start SW 1
- Push start SW 2
Is it turned ON when pressing the push button ignition switch?
Yes : Even if DTC is displayed, the circuit has returned to a normal condition at this time.
Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.No : Replace the keyless access Control Module. Ref. to SECURITY AND LOCKS>KEYLESS ACCESS CONTROL MODULE .