LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2019 >> Forester Base >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Anti-Theft Systems >> Security And Locks - Keyless Access (W/Push Button Start) (Diagnostics) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC B227B: Push Engine Start Switch Input Performance >> Wiring diagram

DTC B227B: Push Engine Start Switch Input Performance: Wiring diagram

Keyless access with push button start system Ref. to WIRING SYSTEM>KEYLESS ACCESS WITH PUSH BUTTON START SYSTEM>WIRING DIAGRAM .

G13228984Courtesy of SUBARU OF AMERICA, INC.
CAUTION:
  1. CHECK DTC  .
    1. Using the Subaru Select Monitor, perform the clear memory of [Keyless Access with Push Button Start]. Ref. to COMMON(DIAG)>CLEAR MEMORY .
    2. Press the push button ignition switch to perform OFF → ACC ON → IGN ON respectively for one minute.
    3. Disconnect and reconnect the keyless access Control Module connector.
    4. Read the DTC of [Keyless Access with Push Button Start] using the Subaru Select Monitor.

      Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .

      Is DTC B227B displayed? (Current malfunction)

      Yes  : Go to  2 .

      No  : Even if DTC is displayed, the circuit has returned to a normal condition at this time.

      Reproduce the failure, and then perform the diagnosis again.

      NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
  2. CHECK HARNESS (OPEN CIRCUIT)  .
    1. Disconnect the push button ignition switch connector.
    2. Disconnect the keyless access Control Module connector.
    3. Using a tester, measure the resistance between the push button ignition switch connector and the keyless access Control Module connector and chassis ground.

      Connector & terminal 

      (i150) No. 2 - (i75) No. 9:

      (i150) No. 7 - (i75) No. 8:

      (i150) No. 5 - Chassis ground

      Is the resistance less than 1 Ω?

      Yes  : Go to  3 .

      No  : Repair or replace the open circuit of harness.

  3. CHECK PUSH BUTTON IGNITION SWITCH UNIT  .

    Perform individual inspection of the push button ignition switch. Ref. to SECURITY AND LOCKS>PUSH BUTTON IGNITION SWITCH .

    Is the check result OK?

    Yes  : Go to  4 .

    No  : Replace the push button ignition switch. Ref. to SECURITY AND LOCKS>PUSH BUTTON IGNITION SWITCH .

  4. CHECK DATA MONITOR  .

    Using the Subaru Select Monitor, check the following items in the [Data Monitor] of [Keyless Access with Push Button Start]. Ref. to KEYLESS ACCESS WITH PUSH BUTTON START (DIAGNOSTICS)>DATA MONITOR .

    • Push start SW 1
    • Push start SW 2

    Is it turned ON when pressing the push button ignition switch?

    Yes  : Even if DTC is displayed, the circuit has returned to a normal condition at this time.

    Reproduce the failure, and then perform the diagnosis again.

    NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.

    No  : Replace the keyless access Control Module. Ref. to SECURITY AND LOCKS>KEYLESS ACCESS CONTROL MODULE .