Starter Relay: Inspection

WARNING: This page is about a different car, the 2019 Subaru Ascent. However, it is still accessible from the selected car via links, so may be relevant.
  1. Check that there is no deformation, cracks or other damages.
  2. Check the resistance between terminals. Replace the relay if it is faulty.
    • Starter relay
      G11252918Courtesy of SUBARU OF AMERICA, INC.
      Terminal No. Inspection conditions Standard
      3 - 4 Always 1 MΩ or more
      3 - 4 Apply battery voltage between terminals 1 and 2. Less than 1 Ω
    • Starter cut relay
      G11252918Courtesy of SUBARU OF AMERICA, INC.
      Terminal No. Inspection conditions Standard
      3 - 4 Always 1 MΩ or more
      3 - 4 Apply battery voltage between terminals 1 and 2. Less than 1 Ω