Related DTC
When the DTCs related to the EVAP system have been stored, the malfunctioning section can be located using the table below.
| Malfunctioning Areas/DTCs | P0441 | P0451 | P0452 | P0453 | P0455 | P0456 | P0458 | P0459 |
|---|---|---|---|---|---|---|---|---|
| Purge valve stuck open | • | • | ||||||
| Purge valve stuck closed | • | |||||||
| Purge valve low output | • | |||||||
| Purge valve high output | • | |||||||
| Canister pressure sensor signal fixed | • | |||||||
| Canister pressure sensor low output | • | |||||||
| Canister pressure sensor high output | • | |||||||
| Gross leak | • | • | ||||||
| Small leak | • |
| Malfunctioning Areas/DTCs | P1449 | P1451 | P2401 | P2402 | P2404 | P2419 | P2420 |
|---|---|---|---|---|---|---|---|
| Reference orifice low-flow | • | ||||||
| Reference orifice high-flow | • | ||||||
| Leak detection pump stuck OFF | • | ||||||
| Leak detection pump stuck ON | • | • | |||||
| Vent valve stuck closed | • | • | |||||
| Vent valve stuck open | • | • | |||||
| Canister filter clogged | • | ||||||
| Pipe clogged | • |
CAUTION:
If the standard pressure difference between 1st check and 2nd check is out of specification, all DTCs (P0455, P0456, P1451, P2404) related to standard pressure are stored.