LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2019 >> Ascent Base >> Repair and Diagnosis >> Electrical >> Gauges >> Instrumentation System & Driver Information Center >> Combination Meter System >> Operation >> Variant Work

Variant Work

Perform when replacing with a new combination meter assembly.

CAUTION: When incorrect information is written by [Reading and Writing of the ECU Configuration Information and Odometer Value], [Write ECU setting save data] and [Write ECU setting 12 columns of models], a new combination meter cannot be used because correct information is not displayed. Obtain another new combination meter and write information again.
Item  Contents 
[Read Control Module Setting Information] Read the setting information from the combination meter before replacement, and save it to the Subaru Select Monitor. (1)
[Write Control Module Setting Information] [Write ECU setting save data] Write the setting information saved by [Read Control module setting information] to the new combination meter. (2)
[Write ECU setting 12 columns of models] Using applied models and option codes, write the setting information to the new combination meter. (2)
[Reading and Writing of the ECU Configuration Information and Odometer Value] Read the setting information and odometer value from the combination meter before replacement, and write them to the new combination meter.
(1) Odometer value reading and storing are not possible.
(2) Odometer value writing is not possible

OPERATION PROCEDURE A. 

CAUTION:
  • Using wire (USB cable) to connect Subaru Select Monior.
  • Carry-over of the odometer value is possible only once. If failed, odometer carry-over cannot be performed anymore.
  • When odometer value reading is performed, the odometer displays "------" and continued use of the combination meter assembly is impossible.
  • When the power supply of the Subaru Select Monitor is turned OFF during work, the odometer value data is cleared and carry-over becomes impossible. Be careful of the state of power supply connection of Subaru Select Monitor.
  1. Read and store the setting information and odometer value.
    1. Connect the Subaru Select Monitor and then turn the ignition switch to ON.
    2. On [Start] screen, select [Diagnosis].
    3. On [Select Vehicle] screen, enter vehicle information and select [OK].
    4. On [Main Menu] screen, select [Each System].
    5. On [Select System] screen, select [Combination Meter], and then select [Next].
    6. On [Select Function] screen, select [Work Support], and then select [Read and Writing of the ECU Configuration Informationn and Odometer Value].
    7. Save under a new name according to the display screen.
    8. When [Do you read the Odometer Value? Odometer of the Meter is locked] is displayed, click the [YES] button.
    9. Confirm that [Read the Odometer Value] is displayed, and then turn the ignition switch to OFF.
  2. Replace the combination meter assembly with a new part. Ref. to Combination Meter .
    CAUTION: Do not perform the following. Otherwise, saved odometer values will be cleared.
    • Turn the power supply of Subaru Select Monitor to OFF.
    • Disconnect the USB cable between Subaru Select Monitor and the interface for Subaru Select Monitor.
    NOTE: The data link connector can be removed. If it is interfering with the work, move it outside the vehicle.
    G00676538Courtesy of SUBARU OF AMERICA, INC.
    (a) Interface for Subaru Select Monitor
    (b) Data link connector
  3. Write the setting information and odometer value.
    NOTE: When the odometer value writing operation is completed correctly, the odometer value is automatically cleared from the Subaru Select Monitor.
    1. [Did you replace the meter?] is displayed. Click the [YES] button.
    2. When [Do you write Odometer Value?] is displayed, click the [YES] button.
    3. When [Completed the writing of Odometer Value. Write the ECU Configuration Information] is displayed, click the [OK] button.
    4. Select the file saved with [Reading and Writing of the ECU Configuration Information and Odometer Value], and click the [Execution] button.
    5. When [Write?] is displayed, select the [YES] button.
    6. Confirm that [Write operation was completed.] is displayed, and click the [OK] button.
  4. Check if the combination meter assembly operates normally.

OPERATION PROCEDURE B. 

NOTE: With [Write ECU setting 12 columns of models], carry-over of odometer value cannot be performed.
  1. Replace the combination meter assembly with a new part. Ref. to Combination Meter 
  2. Write the vehicle data.
    1. Connect the Subaru Select Monitor.
    2. On [Start] screen, select [Diagnosis].
    3. On [Select Vehicle] screen, enter vehicle information and select [Set].
    4. On [Main Menu] screen, select [Each System].
    5. On [Select System] screen, select [Combination Meter], and then select [Enter].
    6. On [Select Function] screen, select [Work Support], and then select [Write Control module setting information].
    7. From the item list, select [Write ECU setting 12 columns of models]. Enter the applied model and click the [OK] button. Ref. to IDENTIFICATION>IDENTIFICATION NUMBER & LABEL LOCATIONS .
    8. Enter the option code and click the [OK] button.
    9. Confirm the vehicle information on [Write ECU setting 12 columns of models] display, and click the [OK] button.
    10. When [Write?] is displayed, select the [Yes] button.
    11. Confirm that [Write operation is complete.] is displayed, and click the [OK] button.
  3. Check if the combination meter assembly operates normally.