Variant Work
Perform when replacing with a new combination meter assembly.
- When the combination meter before replacement can communicate with Subaru Select Monitor is possible ([Read Control module setting information] is workable): Perform the operation procedure A.
- When the combination meter before replacement cannot communicate with Subaru Select Monitor is possible ([Read Control module setting information] is not workable): Perform the operation procedure B.
CAUTION:
When incorrect information is written by [Reading and Writing of the ECU Configuration Information and Odometer Value], [Write ECU setting save data] and [Write ECU setting 12 columns of models], a new combination meter cannot be used because correct information is not displayed. Obtain another new combination meter and write information again.
| Item | Contents | |||||
| [Read Control Module Setting Information] | Read the setting information from the combination meter before replacement, and save it to the Subaru Select Monitor. (1) | |||||
| [Write Control Module Setting Information] | [Write ECU setting save data] | Write the setting information saved by [Read Control module setting information] to the new combination meter. (2) | ||||
| [Write ECU setting 12 columns of models] | Using applied models and option codes, write the setting information to the new combination meter. (2) | |||||
| [Reading and Writing of the ECU Configuration Information and Odometer Value] | Read the setting information and odometer value from the combination meter before replacement, and write them to the new combination meter. | |||||
|
||||||
OPERATION PROCEDURE A.
CAUTION:
- Using wire (USB cable) to connect Subaru Select Monior.
- Carry-over of the odometer value is possible only once. If failed, odometer carry-over cannot be performed anymore.
- When odometer value reading is performed, the odometer displays "------" and continued use of the combination meter assembly is impossible.
- When the power supply of the Subaru Select Monitor is turned OFF during work, the odometer value data is cleared and carry-over becomes impossible. Be careful of the state of power supply connection of Subaru Select Monitor.
- Read and store the setting information and odometer value.
- Connect the Subaru Select Monitor and then turn the ignition switch to ON.
- On [Start] screen, select [Diagnosis].
- On [Select Vehicle] screen, enter vehicle information and select [OK].
- On [Main Menu] screen, select [Each System].
- On [Select System] screen, select [Combination Meter], and then select [Next].
- On [Select Function] screen, select [Work Support], and then select [Read and Writing of the ECU Configuration Informationn and Odometer Value].
- Save under a new name according to the display screen.
- When [Do you read the Odometer Value? Odometer of the Meter is locked] is displayed, click the [YES] button.
- Confirm that [Read the Odometer Value] is displayed, and then turn the ignition switch to OFF.
- Replace the combination meter assembly with a new part. Ref. to Combination Meter .CAUTION: Do not perform the following. Otherwise, saved odometer values will be cleared.
- Turn the power supply of Subaru Select Monitor to OFF.
- Disconnect the USB cable between Subaru Select Monitor and the interface for Subaru Select Monitor.
NOTE: The data link connector can be removed. If it is interfering with the work, move it outside the vehicle.(a) Interface for Subaru Select Monitor (b) Data link connector - Write the setting information and odometer value.NOTE: When the odometer value writing operation is completed correctly, the odometer value is automatically cleared from the Subaru Select Monitor.
- [Did you replace the meter?] is displayed. Click the [YES] button.
- When [Do you write Odometer Value?] is displayed, click the [YES] button.
- When [Completed the writing of Odometer Value. Write the ECU Configuration Information] is displayed, click the [OK] button.
- Select the file saved with [Reading and Writing of the ECU Configuration Information and Odometer Value], and click the [Execution] button.
- When [Write?] is displayed, select the [YES] button.
- Confirm that [Write operation was completed.] is displayed, and click the [OK] button.
- Check if the combination meter assembly operates normally.
OPERATION PROCEDURE B.
NOTE:
With [Write ECU setting 12 columns of models], carry-over of odometer value cannot be performed.
- Replace the combination meter assembly with a new part. Ref. to Combination Meter
- Write the vehicle data.
- Connect the Subaru Select Monitor.
- On [Start] screen, select [Diagnosis].
- On [Select Vehicle] screen, enter vehicle information and select [Set].
- On [Main Menu] screen, select [Each System].
- On [Select System] screen, select [Combination Meter], and then select [Enter].
- On [Select Function] screen, select [Work Support], and then select [Write Control module setting information].
- From the item list, select [Write ECU setting 12 columns of models]. Enter the applied model and click the [OK] button. Ref. to IDENTIFICATION>IDENTIFICATION NUMBER & LABEL LOCATIONS .
- Enter the option code and click the [OK] button.
- Confirm the vehicle information on [Write ECU setting 12 columns of models] display, and click the [OK] button.
- When [Write?] is displayed, select the [Yes] button.
- Confirm that [Write operation is complete.] is displayed, and click the [OK] button.
- Check if the combination meter assembly operates normally.