LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2018 >> WRX Base >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Continuously Variable Transmission (Diagnostics)) >> Subaru Select Monitor >> Operation >> Read Current Data

Read Current Data

WARNING: This page is about a different variant/trim than selected.
  1. On «Start» display, select «Diagnosis».
  2. On «Vehicle selection» display, input the vehicle information and select «Confirmed».
  3. On «Main Menu» display, select «Each System».
  4. On «Select System» display, select «Transmission Control System».
  5. On «Select Function» display, select «Data Monitor».
    Display Contents Unit of measure
    Engine Speed Engine speed signal transmitted from the ECM. Calculated from crankshaft position sensor signal. TCM input value. rpm
    Turbine Revolution Speed Turbine rotation speed which is based on the primary pulley rotation speed calculated by the TCM using signals from the primary speed sensor, and is accelerated by the reduction gear ratio. rpm
    Accel opening angle Accelerator pedal opening angle transmitted from the ECM. Value calculated from the accelerator pedal position sensor output. TCM input value. %
    Front Wheel Speed Front wheel speed calculated from the forward/reverse clutch output axis rotation speed. km/h or MPH
    Rear Wheel Speed Rear wheel speed calculated from the forward/reverse clutch output axis rotation speed. km/h or MPH
    ATF Temperature Value calculated from the ATF temperature sensor output value. ATF temperature of the oil pan section. °C or °F
    Lock Up Duty Ratio Lock-up duty solenoid control duty ratio. TCM output value. %
    Lock-Up ON/OFF Solenoid Lock-up ON/OFF solenoid drive signal. Set to ON at a lockup condition. TCM output value. ON or OFF
    Transfer Duty Ratio Transfer duty solenoid control duty ratio. TCM output value. %
    Actual Gear Ratio Current gear ratio (rotation ratio of the pulley) calculated from the primary pulley axis rotation speed and the secondary pulley axis rotation speed. -
    Primary Rev Speed Primary pulley rotation speed calculated by the TCM using signals from the primary speed sensor. rpm
    Secondary Rev Speed Secondary pulley rotation speed calculated by the TCM using signals from the secondary speed sensor. rpm
    Front Wheel Speed Front wheel rotation speed calculated from the forward/reverse clutch output axis rotation speed. rpm
    Rear Wheel Speed Rear wheel rotation speed calculated from the forward/reverse clutch output axis rotation speed. rpm
    Stop Light Switch Stop light SW signal. Set to ON when the brake pedal is depressed. TCM input value. ON or OFF
    Secondary Set Current Value of the indicator current for controlling the secondary solenoid calculated by the TCM. mA
    Secondary Actual Current Actual current value of the secondary solenoid. TCM output value. mA
    F&R Linear Solenoid Set Current Value of the indicator current for controlling the F&R linear solenoid calculated by the TCM. mA
    F&R Linear Solenoid Actual Current Actual current value of the F&R linear solenoid. TCM output value. mA
    ECU ACC Battery voltage. TCM input value. V
    Primary UP Duty Primary UP solenoid control duty ratio. TCM output value. %
    Primary DOWN Duty Primary DOWN solenoid control duty ratio. TCM output value. %
    P Range Inhibitor SW signal. Set to ON when the select lever is in P range. TCM input value. ON or OFF
    R Range Inhibitor SW signal. Set to ON when the select lever is in R range. TCM input value. ON or OFF
    N Range Inhibitor SW signal. Set to ON when the select lever is in N range. TCM input value. ON or OFF
    D Range Inhibitor SW signal. Set to ON when the select lever is in D range. TCM input value. ON or OFF
    SI Drive mode(Display) Currently selected SI-DRIVE mode, which is transmitted from meter. Determined by the SI-DRIVE SW operation. TCM input value. I, S or S#
    SI Drive mode(Control) Current SI-DRIVE mode in ECM control, which is transmitted from the ECM. Determined by adjusting the mode determined by the SI-DRIVE SW operation inside the ECM. TCM input value. I, S or S#
    Shift Step in Manual Mode Gear shift position in manual mode or in multi-stage shifting mode. TCM output value. -
    Triptronic Mode Switch Manual mode SW signal. Set to ON when the select lever is in the manual shift gate. TCM input value. ON or OFF
    Up Switch Status of the paddle shift up SW. Set to ON when the plus (+) side of the steering wheel paddle shift is pulled. TCM input value. ON or OFF
    Down Switch Status of the paddle shift down SW. Set to ON when the minus (-) side of the steering wheel paddle shift is pulled. TCM input value. ON or OFF
    secondary pressure sensor voltage. Voltage value after an analog/digital conversion is done inside the TCM using the signal input from the secondary pressure sensor. TCM input value. V
    ATF Temp sensor voltage. Sensor voltage value input from the ATF temperature sensor to the TCM. TCM input value. V
    Diagnosis Lamp Transmission failure detection status. Set to ON when a failure is detected. AT oil temperature warning light blinks at 2 Hz. TCM output value. ON or OFF
    ATF Temperature Lamp ATF high temperature detection status. Set to ON when high temperature is detected. AT oil temperature warning light illuminates. TCM output value. ON or OFF
    AT learning AT initial learning completion status. AT oil temperature warning light blinks at 4 Hz when the learning is not completed. TCM output value. Complete or Not Completed
    Ignition SW ON Count Number of times the ignition switch is turned ON since the vehicle was manufactured. times
    Count Shows whether the elapsed time counter after turning ON the ignition switch is synchronized with the integrated unit (master unit) or an original counter. "Common" means the integrated unit, and "Originally" means that the original counter is used. -
    Time Count Shows the elapsed time after turning ON the ignition switch. ms
    Actual Secondary Pressure Pressure value applied to the secondary pulley cylinder (line pressure) detected by the secondary pressure sensor. MPa
    System Voltage Power supply voltage supplied to the backup power supply ( battery voltage). V
    NOTE: For detailed operation procedures, refer to "Application help".