Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Throttle position when the ignition switch is ON - Throttle minimum stop position | < 2.6% (sensor 1) < 2.6% (sensor 2) |
Time needed for diagnosis: 200 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.