DTC P2009: TGV Control Circuit Low Bank 1: Notes
DTC detecting condition:
Immediately at fault recognition
CAUTION:
- After servicing or replacing faulty parts, perform Clear Memory Mode Ref. to ENGINE (DIAGNOSTICS) (EXCEPT FOR STI)>Clear Memory Mode>OPERATION , and inspection mode Ref. to ENGINE (DIAGNOSTICS) (EXCEPT FOR STI)>Inspection Mode>PROCEDURE .
- Use the check board when measuring the ECM terminal voltage and resistance.
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>Engine Electrical System>WIRING DIAGRAM .
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR
.
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Measure the voltage between ECM connector and engine ground.
Connector & terminal
(E159) No. 14 (+) - Engine ground (-):
(E159) No. 30 (+) - Engine ground (-):
Is the voltage 5 V or more?
Yes: Repair the short circuit to power in harness between ECM connector and tumble generator valve actuator RH connector.
No: Replace the tumble generator valve actuator RH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (EXCEPT FOR STI)>Tumble Generator Valve Actuator .