Execution Condition
EXECUTION CONDITION - DIAGNOSIS 1
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Soaking time | ≥ 21600 s |
| Block heater judgment | Completed |
| Block heater operation | Not in operation |
EXECUTION CONDITION - DIAGNOSIS 2
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Engine coolant temperature | ≥ 60°C (140°F) |
| Integrated value of intake air amount | ≥ 5500 g |
| Number of experiences under following driving conditions | ≥ 3 times |
| Duration of driving condition 1 | ≥ 10 s |
| Vehicle speed | ≥ 40 km/h (24.9 MPH) |
| and | |
| Amount of intake air | ≥ 10 g/s (0.4 oz/s) |
| Duration of driving condition 2 | ≥ 15 s |
| Vehicle speed | < 4 km/h (2.5 MPH) |