Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Main feedback | In operation |
| Rear oxygen sensor voltage when fuel cut has completed | ≥0.15V |
| (Elapsed time of fuel cut | ≥3000ms |
| Fuel shut-off function from above) | Not in operation |
| Estimated element temperature of rear oxygen sensor when fuel cut has completed | ≥500°C (932°F) |
| Amount of intake air | ≥16g/s (0.56oz/s) |