Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Common condition (Phase 1, Phase 2) | |
| Battery voltage | ≥ 10.9 V |
| Barometric pressure | ≥ 75.1 kPa (563 mmHg, 22.2 inHg) |
| Fuel level | ≥ 9 L |
| Phase1 | |
| Integrated purge air amount since engine starting | ≥ 72 g |
| (Purge control duty ratio | = 0% |
| for time) | ≥ 1 s |
| Ambient air temperature | > 4.4 °C (39.9 °F) and < 35 °C (95 °F) |
| Intake air amount per 1 second | > Map |
| Commanded solenoid valve for secondary purge (High Pressure Purge Line) | Open |
MAP SPECIFICATION
| Fuel level L (US gal) | 0 (0) | 10 (2.64) | 20 (5.28) | 30 (7.93) | 40 (10.57) | 50 (13.21) | 60 (15.85) |
|---|---|---|---|---|---|---|---|
| Intake air amount per 1 second (g/s) | 80 | 80 | 60 | 60 | 60 | 60 | 60 |