Diagnostic Method
Compare the diagnostic value with the threshold value, and if a condition meeting the malfunction criteria listed below continues for 10 s x 3 time(s) or more, judge that there is a fault in the fuel system.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Offset amount of main feedback compensation | ≥ Value from Map |
MAP SPECIFICATION
| Amount of air (g/s (oz/s)) | 0 (0) | 2.34375 (0.08) | 4.6875 (0.17) | 7.03125 (0.25) | 9.375 (0.33) | 11.71875 (0.41) | 14.0625 (0.5) |
| Threshold Value | 1.35 | 1.35 | 1.35 | 1.35 | 1.35 | 1.35 | 1.35 |
Time Needed for Diagnosis: 10 s x 3 time(s)
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.