Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Common condition: (Phase 1, Phase 2) Battery voltage |
≥ 10.9 V |
| Barometric pressure | ≥ 75.1 kPa (563 mmHg, 22.2 inHg) |
| Fuel level | ≥ 9L |
| Phase1 Integrated purge air amount since engine starting |
≥ 72 g |
| (Purge control duty ratio | = 0% |
| for time) | ≥ 1 s |
| Ambient air temperature | > 4.4°C and < 35°C |
| Intake air amount per 1 second | > Map |
| Commanded solenoid valve for secondary purge (High Pressure Purge Line) |
Open |
MAP SPECIFICATION
| Fuel level L (US gal) | 9 (2.64) | 10 (5.26) | 20 (5.28) | 30 (7.93) | 40 (10.57) | 50 (13.21) | 60 (15.85) |
| Intake air amount per 1 second (g/s) | 80 | 80 | 60 | 60 | 60 | 60 | 60 |