DTC P2011: TGV Control Circuit/Open Bank 2: Notes
DTC detecting condition:
Immediately at fault recognition
CAUTION:
Wiring diagram:
Engine Electrical System Ref. to WIRING DIAGRAM , Engine Electrical System.
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY LH CONNECTOR.
Connector & terminal (E158) No. 39 - (E51) No. 5: (E158) No. 26 - (E51) No. 4: |
Is the resistance less than 1 Ω? | Go to step 2 | Repair the harness and connector.
NOTE:
In this case, repair the following item:
|
| 2 CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY LH CONNECTOR. Measure the resistance between ECM connector and chassis ground. Connector & terminal (E158) No. 39 - Chassis ground: (E158) No. 26 - Chassis ground: |
Is the resistance 1 MΩ or more? |
Go to step 3 | Repair the short circuit to ground in harness between ECM connector and tumble generator valve assembly LH connector. |
| 3 CHECK FOR POOR CONTACT. Check for poor contact of tumble generator valve assembly LH connector. |
Is there poor contact of the tumble generator valve assembly LH connector? | Repair the poor contact of tumble generator valve assembly LH connector. | Replace the tumble generator valve assembly LH. Ref. to TUMBLE GENERATOR VALVE |