LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2017 >> Outback 2.5i >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (Diagnostics) (P0700 To P2097) (H4DO) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P2011: TGV Control Circuit/Open Bank 2 >> Notes

DTC P2011: TGV Control Circuit/Open Bank 2: Notes

DTC detecting condition: 

Immediately at fault recognition

CAUTION:
  • After servicing or replacing faulty parts, perform Clear Memory Mode Ref. to OPERATION , Clear Memory Mode, and Inspection Mode Ref. to PROCEDURE , Inspection Mode.
  • Use the check board when measuring the ECM terminal voltage and resistance.

Wiring diagram: 

Engine Electrical System Ref. to WIRING DIAGRAM , Engine Electrical System.

Fig 1: TGV Control - Wiring Diagram (Bank 2)
G11583460Courtesy of SUBARU OF AMERICA, INC.
Step Check Yes No
1 CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY LH CONNECTOR. 
  1. Turn the ignition switch to OFF.
  2. Disconnect the connector from ECM.
  3. Disconnect the connector from tumble generator valve assembly LH.
  4. Measure the resistance of harness between ECM connector and tumble generator valve assembly LH connector.

Connector & terminal 
(E158) No. 39 - (E51) No. 5: 
(E158) No. 26 - (E51) No. 4: 
Is the resistance less than 1 Ω? Go to step Repair the harness and connector.
NOTE: In this case, repair the following item:
  • Open circuit in harness between ECM connector and tumble generator valve assembly LH connector
  • Poor contact of coupling connector
2 CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY LH CONNECTOR. 
Measure the resistance between ECM connector and chassis ground.
Connector & terminal 
(E158) No. 39 - Chassis ground: 
(E158) No. 26 - Chassis ground: 
Is the resistance 1 MΩ or
more?
Go to step Repair the short circuit to ground in harness between ECM connector and tumble generator valve assembly LH connector.
3 CHECK FOR POOR CONTACT. 
Check for poor contact of tumble generator valve assembly LH connector.
Is there poor contact of the tumble generator valve assembly LH connector? Repair the poor contact of tumble generator valve assembly LH connector. Replace the tumble generator valve assembly LH. Ref. to TUMBLE GENERATOR VALVE