DTC P2009: TGV Control Circuit Low Bank 1: Notes
DTC detecting condition:
Immediately at fault recognition
CAUTION:
Wiring diagram:
Engine Electrical System Ref. to WIRING DIAGRAM , Engine Electrical System.
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR.
Connector & terminal (E158) No. 13 (+) - Chassis ground (-): (E158) No. 52 (+) - Chassis ground (-): |
Is the voltage 5 V or more? | Repair the short circuit to power in harness between ECM connector and tumble generator valve actuator RH connector. | Replace the tumble generator valve actuator RH. Ref. to TUMBLE GENERATOR VALVE ACTUATOR |