LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2017 >> Forester 2.0XT Premium >> Repair and Diagnosis (Single Page) >> Electrical >> Gauges >> Multi-Function Display (Diagnostics) >> Data Monitor >> List

Data Monitor: List

Items to be displayed Unit of measure Content Note
MFD hardware fail flag Normal/MFD Fail MFD abnormal status -
MFD U-ART communication error flag Normal/MFD U-ART Fail -
MFD CAN communication error flag Normal/MFD CAN Fail -
MFD destination abnormal flag Normal/MFD destination error -
MFD failure information No error High-speed CAN error counter abnormal High-speed CAN bus OFF detection High-speed CAN data abnormal High-speed CAN data not received UART data abnormal UART data not received Break the wire of IGN System Microcomputer fail GERDA Malfunction -
Birthday1 setting M - Birthday setting value -
Birthday1 setting D - -
Birthday2 setting M - Birthday setting value -
Birthday2 setting D - -
Anniversary1 setting M - Anniversary setting value -
Anniversary1 setting D - -
Anniversary2 setting M - Anniversary setting value -
Anniversary2setting D - -
Driving record1 setting Yard - Driving record 1 setting value -
Driving record1 setting Time - -
Driving record1setting fuel cons. Ave. - -
Driving record1 setting M - -
Driving record1 setting D - -
Driving record2 setting DIS - Driving record 2 setting value -
Driving record2 setting Time - -
Driving record2setting fuel cons. Ave. - -
Driving record2 setting M - -
Driving record2 setting D - -
Clock/OFF setting OFF External air temperature + analog clock External air temperature + digital clock Clock display setting -
Engine oil maintenance setting Y - Oil maintenance setting value -
Engine oil maintenance setting M - -
Engine oil maintenance setting D - -
Engine oil maintenance setting meter - -
Oil filter maintenance setting Y - Oil filter maintenance setting value -
Oil filter maintenance setting M - -
Oil filter maintenance setting D - -
Oil filter maintenance setting meter - -
Tire maintenance setting Y - Tire maintenance setting value -
Tire maintenance setting M - -
Tire maintenance setting D - -
Tire maintenance setting meter - -
Maintenance schedule Y - Periodic inspection setting value -
Maintenance schedule M - -
Maintenance schedule D - -
Maintenance schedule meter - -
Sub-meter(left) setting NO1 Indication OFF Avg. Speed ODO fuel efficiency ECVT Fluid Temp. Accel. Opening Angle Section time Section distance Section fuel efficiency Meter display setting -
Sub-meter(left) setting NO2 Analog display Digital display Meter display setting -
Sub-meter(center) setting NO1 Indication OFF Avg. Speed ODO fuel efficiency ECVT Fluid Temp. Accel. Opening Angle Section time Section distance Section fuel efficiency Meter display setting -
Sub-meter(center) setting NO2 Analog display Digital display Meter display setting -
Sub-meter(right) setting NO1 Indication OFF Avg. Speed ODO fuel efficiency ECVT Fluid Temp. Accel. Opening Angle Section time Section distance Section fuel efficiency Meter display setting -
Sub-meter(right) setting NO2 Analog display Digital display Meter display setting -
MFD brightness setting NO1 - MFD setting -
MFD brightness setting NO2 - MFD setting -
MFD contrast setting NO1 -5 - +5 MFD setting -
MFD contrast setting NO2 -5 - +5 MFD setting -
ECO evaluation ON-OFF setting OFF/ON MFD setting -
Info area setting OFF Average Fuel Efficiency FUEL CONS Range MFD setting -
Menu language setting (Individual language) MFD setting -
Buzzer volume setting OFF Small Big MFD setting -
Fuel cons. Setting 00/OFF MFD setting -
Auto Start Stop interrupt display setting OFF/ON MFD setting Not applicable
Welcome display ON-OFF setting OFF/ON MFD setting -
Self check ON-OFF setting OFF/ON MFD setting -