Check Ambient Temperature Meter System Communication Circuit
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK AMBIENT SENSOR POWER SUPPLY
.
Connector & terminal (F78) No. 1 (+) - Chassis ground (-): |
Is the voltage 4 V or more? | Go to step 2 . | Check the harness for open or short between the fuse and MFD. |
2 CHECK HARNESS BETWEEN AMBIENT SENSOR AND COMBINATION METER ASSEMBLY
.
|
Is harness normal? | Go to step 3 . | Repair or replace the harness. |
| 3 CHECK AMBIENT SENSOR
. Check the ambient sensor. Ref. to INSPECTION , Ambient Sensor. |
Is the ambient sensor operating properly? | Go to step 4 . | Replace the ambient sensor. |
4 CHECK AMBIENT TEMPERATURE DISPLAY
.
|
Does the ambient temperature display 25°C (77°F)? | Repair the poor contact between the ambient sensor and harness connector. | Go to step 5 . |
| 5 CHECK CURRENT DATA
. Using the Subaru Select Monitor, display the data of «Ambient Air Temperature».
NOTE:
For detailed operation procedures, refer to
"Application help".
|
Is the ambient temperature of 25°C (77°F) output? | Go to step 6 . | Replace the meter - main assembly. Ref. to COMBINATION METER . |
6 CHECK MFD
.
|
Does the ambient temperature display 25°C (77°F)? | Replace the MFD. | Replace the meter - main assembly. Ref. to COMBINATION METER . |